FireLine System Protocol Manual
9
Raveon Technologies Corp.
Example: Request the software version from modem 1234.
RPR 1234 ATBD
User enters request to station 1234
<RPR>
FROM=1234
ATBD=3
</RPR>
Response back from remote modem 1234
indicates that the modem’s baud rate setting is
3 (9600 bps)
RPR ATAT, RPR ATBT, and RPR ATCT
RPR ATAT xxxx Request the serial port time-out parameters of remote modem xxxx
where xxxx is 0000 thru FFFE.
Example: Request the software version from modem 1234.
RPR 1234 ATAT
User enters request to station 1234
<RPR>
FROM=1234
ATAT=500
</RPR>
Response back from remote modem 1234
indicates that the modem’s AT before-time
period is set to 500mS.
RPR ATNB, and RPR ATNS
RPR ATAT xxxx Request the serial port parameters.
Example: Request the number of stop bits
RPR 1234 ATNS
User enters request to station 1234
<RPR>
FROM=1234
ATNS=1
</RPR>
Response back from remote modem 1234
indicates that the modem’s serial port uses
one stop bit.
5.4. RPR Error Responses
If an invalid RPR request is transmitted, the FireLine will output an error message
that can be used to determine the source of the error.
Wrong or invalid ID
If a FireLine sends and RPR request to a remote modem with an ID that does not
exist in the network, is out of range, turned off, or has the RPR feature disabled,
the FireLine will respond by outputting a TIMEOUT message from its serial port
after about 5 seconds of not receiving a response from the remote modem.
For Example: